Body-heat wearable charger

This is an idea, not a product. Nothing here has been built or tested unless a linked technology profile says so.
The problem
People who wear small health or fitness sensors may want to avoid frequent battery changes. Body heat may offer a way to keep a very low-power sensor running, but this has not been shown outside the laboratory.
The idea
A first version would be a thin, flexible thermoelectric strip worn under a strap against the skin, feeding a small energy store that trickles power to one low-power sensor. It would top up a sensor that already needs very little power rather than replace a battery, and the first target is a bench check of the power output, not a product.
Enabling technology
- Thermoelectric generators: Thermoelectric generators turn a temperature difference directly into electricity with no moving parts. Radioisotope versions have powered spacecraft and Mars rovers, while wearable and waste-heat versions remain limited by low conversion efficiency and small usable temperature differences.
What stands in the way
- Measured output is small. The 2022 wearable study reported 2.19 microwatts per square centimetre from body heat alone at a 5.5 degree Celsius temperature difference, which may be too low for most sensors without a large patch or a very low-power circuit.
- Output depends on the surroundings. In the 2022 study, body-heat-only output fell almost to nothing when ambient temperature reached 35 degrees Celsius, so a warm room or direct sun may remove the temperature gap the device needs.
- The 2022 device was tested on an insulating film at a 35 degree surface and 25 degree ambient, not on live skin, so real-skin output is not known.
- A single figure of merit (ZT) may not describe device efficiency, according to a 2018 preprint, and a 2024 review reports efficiency capped at half the Carnot value for ZT of 1 to 3. Both points make it harder to predict output from a material datasheet.
- A usable charger also needs a voltage converter, an energy store and comfortable, sweat-tolerant packaging. The thermoelectric profile does not cover these parts, and they are not yet tested together.
A cheap way to test it
Bench test only, with no human subjects. Mount a commercial thermoelectric module between a heated plate set to a skin-like surface temperature and a cold side held at a controlled ambient temperature. Record the temperature difference with two thermocouples, then record open-circuit voltage and power into a fixed load. Divide power by module area so results can be set against the per square centimetre figure. Repeat at several temperature differences, including about 5.5 degrees Celsius, and again at a high ambient temperature near 35 degrees Celsius. Before testing, the team writes down the acceptable margin around 2.19 microwatts per square centimetre for the 5.5 degree point. Pass if power rises with temperature difference, the 5.5 degree result falls within the written margin of the 2022 figure, and repeat runs agree. Fail if the 5.5 degree result is outside that margin, if output shows no clear trend, or if output at the smallest difference is not measurably above the sensor's power draw, which is written down before testing. Then repeat the set-up under the 35 degree surface and 25 degree ambient conditions used for the 2022 film tests, so the lab method can be compared with the study's own test conditions.